TEST PROCEDURE OF POLYMER

 

TEST PROCEDURE OF POLYMER





DENSITY

Equipment - mud balance

1) The apparatus consists of a balance rod with a container on one end and a center weight rider on the

other side fitted on either side of a knife edge fulcrum.

2) A spirit Level indicator is fitted to the balancing rod to indicate the level.

3) The balancing rod is calibrated (to read within 5 gm/ml) to indicate the density.

Procedure

a) Sample collected from the bottom of the pile bore by the mud sampler is poured into the container

fitted to the balancing rod.

b) The walls of the container are taped to free any bubbles trapped in the sampler.

c) The lid of the container is closed tightly. Make sure that some of the samples are forced out of the

container properly.

d) Clean the outside of the container properly.

e) Place the balancing rod with the container on the knife edge fulcrum.

f) Move the center weight rider forward or backward so that the level indicator on the balancing rod

shows that the rod is balanced.

g) Specific gravity can be directly read from calibration on the balancing rod corresponding to the rider

VISCOSITY

Equipment - marsh funnel

1) The apparatus consist of the following:

2) Funnel with sieve on top to filter the sample while pouring into the funnel and a small orifice at the

bottom.

3) A graduated cup to be used as a receiver.

4) Stop watch.

Procedure

1) Cover the funnel orifice with a finger and pour freshly sampled drilling fluid through the service into

the clean, upright funnel. Fill until the fluid reaches the bottom of the screen.

2) Remove the finger and start the stopwatch. Measure the time for mud to fill one quart (946cm3)

mark of the cup.

3) Report the time to the nearest second as marsh Funnel viscosity.

PH Value

Equipment - Electronic pH meter

The apparatus consists of the following:

1) The sensor rod

2) Electronic display unit

PROCEDURE

1) Switch on the apparatus

2) Insert the sensor rod into the sample and wait until the reading stabilizes.

3) The pH value can be directly read form the display